CO2 Incubator ICO50 Memmert – Technical Data

Temperature

  • Working-temperature range: 5 °C above ambient temperature up to +50 °C
  • Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors)
  • Setting temperature range: +18 to +50 °C
  • Setting accuracy temperature: 0.1 °C
  • Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
  • Temperature variation in chamber at +37 °C: +/- 0.3 K
  • Temperature fluctuations with time at 37 °C: +/- 0.1 K

Humidity

  • Humidity control (standard): Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 %
  • Setting accuracy humidity: 0.5 % rh
  • Setting range active humidity control (with option K7): 40 to 97 % rh and rh-Off

Control of Standard Components

  • CO2 control: Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation
  • Adjustment range CO2: 0 to 20 % CO2
  • Setting accuracy CO2: 0.1%
  • Variation in time CO2: +/- 0.2 % CO2
  • Adjustment range O2: 1 to 20 % O2
  • Setting accuracy O2: 0.1 % O2

Control Technology

  • ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
  • Language setting: German, English, Spanish, French, Polish, Czech, Hungarian
  • Function SetpointWAIT: The process time does not start until the set temperature is reached
  • Adjustable parameters: Temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime/wintertime

Communication

  • Interface: Ethernet LAN, USB
  • Documentation: Programme stored in case of power failure
  • Programming: AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

  • AutoSAFETY: Additionally integrated over- and undertemperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
  • Autodiagnostic system: Integral fault diagnostics for temperature and CO2
  • Alarm: Visual and acoustic

Heating Concept

  • 6 sides: Large-area multi-function heating system on four sides with additional door and back heating to avoid condensation

Standard Equipment

  • Works calibration certificate:
    • At +37 °C, 5 % CO2 and 90 % rh (requires option K7); standard equipment for units with active humidity control
    • At +37 °C, 5 % CO2, 90 % rh and 10 % O2 (requires option K7 and option T6); standard equipment for units with O2 control
    • Incl. works calibration certificate (measuring point chamber centre) at +37°C, 5 % CO2 for standard units
  • Door: Fully insulated stainless steel door with 2-point locking (compression door lock)
  • Inner door: Inner glass door with opening (8 mm Ø) to take gas sample
  • CO2 connection set: Hose with coupling and clamp
  • Standard accessories: Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber)
  • Internals: 1 perforated stainless steel shelf/shelves
  • Water dish: 1 stainless steel water dish

Stainless Steel Interior

  • Dimensions (w x h x d): 400 x 425 x 330 mm (d less 35 mm for fan)
  • Material: 1.4301 (ASTM 304), corrosion resistant
  • Volume: 56 l
  • Max. number of internals: 5
  • Max. loading of chamber: 75 kg
  • Max. loading per internal: 15 kg

Textured Stainless Steel Casing

  • Dimensions (w x h x d): 559 x 795 x 521 mm (d +56 mm door handle)
  • Housing: Rear zinc-plated steel

Electrical Data

  • Voltage Electrical load:
    • 230 V, 50/60 Hz, approx. 1100 W
    • 115 V, 50/60 Hz, approx. 1100 W

Ambient Conditions

  • Set Up:
    • The distance between the wall and the rear of the appliance must be at least 15 cm.
    • The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
  • Ambient temperature: 10 °C to 35 °C
  • Humidity rh: Max. 70 %, non-condensing
  • Altitude of installation: Max. 2,000 m above sea level
  • Overvoltage category: II
  • Pollution degree: 2

Packing/Shipping Data

  • Transport information: The appliances must be transported upright
  • Customs tariff number: 8419 8998
  • Country of origin: Federal Republic of Germany
  • WEEE-Reg.-No.: DE 66812464
  • Dimensions approx incl. carton (w x h x d): 730 x 950 x 640 mm
  • Net weight: Approx. 55 kg
  • Gross weight carton: Approx. 74 kg