ADVANCED CHEMILUMINESCENCE IMAGING SYSTEM, SIMILAR TO BIO-RAD CHEMIDOC MP Azzota
W5000 Chemiluminescence Imaging Device
Overview
The W5000 is an advanced imaging device designed for chemiluminescence technology, equipped with a high-sensitivity cooled camera boasting 9 million pixels. It provides fast, accurate, and high-throughput detection and imaging, making it ideal for applications in life sciences, medicine, and environmental protection. Its features and specifications are comparable to the Bio-Rad ChemiDoc MP.
Key Features
- Real-time Imaging:
- Monitors and displays changes in sample signals during the exposure process in real-time.
- Highlights overexposed areas to prevent loss of detail.
- Time Imaging:
- Generates every frame image within the exposure time upon completion.
- Allows selection of any frame as the final output.
- Time Accumulation:
- Continues exposure for samples with insufficient initial exposure.
- Builds on previously accumulated exposure time for enhanced imaging.
- Automatic Exposure:
- Utilizes intelligent exposure technology to quickly determine optimal exposure time.
- Combines time imaging and time accumulation for optimal image results in one operation.
Advanced Chemiluminescence Imaging System Specifications
- Dimensions:
- 400 mm x 371 mm x 700 mm
- Camera:
- Pixel Resolution: 9 million pixels
- Image Resolution: 3000 x 3000 pixels
- Pixel Size: 3.76 μm x 3.76 μm
- Target Size: 1″ (11.28 mm x 11.28 mm)
- Full Well Capacity: 16.5 ke- (HCG), 50.5 ke- (LCG)
- Readout Noise: 1.24 e- (HCG), 3.22 e- (LCG)
- Dark Current: 0.0003 e-/s/pixel @ -15°C
- Signal-to-Noise Ratio: 42.2 dB (HCG), 47 dB (LCG)
- Exposure Time: 0.1 ms to 1 hour
- Binning Mode: 1×1, 2×2, 3×3
- Grayscale: 16-bit (65,536 levels)
- Cooling: Cooled to -40°C relative to ambient temperature
- Camera Type: Black and White Camera
- Lens:
- Aperture: F0.95 to F16
- Focal Length: 17 mm
- Type: Fixed Focus Lens
- Light Source:
- Type: Bright Field Light Source (Downward-facing LED white light, symmetrically distributed on both sides)
- Dark Box:
- Light Isolation: Fully light-sealed to block environmental light
- Door Control: Sensor-controlled bright field light source
- Field of View: 136 mm x 136 mm (expandable to 200 mm x 200 mm)
- Software Functions:
- Real-time Imaging: Displays sample changes in real-time.
- Overexposure Indication: Highlights areas of overexposure.
- Time Imaging: Allows selection of any frame within the exposure period.
- Auto Exposure: Automatically determines the optimal exposure time.
The W5000 chemiluminescence imaging system combines high sensitivity, detailed imaging capabilities, and user-friendly features, making it a robust tool for various scientific and medical applications.





