Jual Oxygen Meter with Rugged Field Dissolved Oxygen Electrode HQ1130 Portable Dissolved 5 m Cable Hach.
Oxygen Meter with Rugged Field Dissolved Oxygen Electrode HQ1130 Portable Dissolved Hach Specifications
Technical Attributes
- Accessories Included: USB charger, power cable, and clips
- Automatic Buffer Recognition: Yes
- Backlight: Yes
- Barometric Pressure Measurement: Automatic compensation of DO when using an LDO or LBOD probe
- Cable Length: 5 m
- Calibration Intervals/Alerts/Reminder: Off, selectable from 2 hours to 7 days
- Certifications: CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
- Data Export: USB connection to PC or USB storage device (limited to the storage device capacity)
- Data Memory: 5000 data points
- Data Storage: Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
- Dimensions (H x W x D): 63 mm x 97 mm x 220 mm
- Display: Up to 3 parameters at a time, dependent on HQ model
- Display Type: 536×336 Mono-TFT
- DO Measurement Range: 0.1 – 20.0 mg/L (ppm), 1 – 200% saturation
- DO Resolution: 0.1
- Enclosure Rating: IP67 (with battery compartment installed)
- GLP Features: Date; Time; Sample ID; Operator ID; Calibration
- Inputs: 1
- Instrument: Portable
- ISE Direct Measurement Range: No
- ISE Electrode Calibration: No
- Kit: Yes
- Languages: English, Chinese – Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
- Lock Function: Continuous / Auto-stabilization (“press to read”) / At Interval
- Measurement Method: Probe specific programmed method settings
- Model: HQ1130 DO/1 Channel
- mV Measurement at Stable Reading: No
- mV Measurement Range: No
- mV Resolution: 0.1 mV
- Operating Error Messages: Clear text error messages displayed
- Operating Humidity: 90% (non-condensing)
- Operating Interface: Soft Touch Keypad
- Operating Temperature: 0 – 60 °C
- Parameter: Dissolved Oxygen (DO)
- Power Supply: Rechargeable lithium-ion battery 18650 (internal). Class II, USB power adapter: 100 – 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
- Probe Type: Intellical Standard Laboratory or Rugged Field
- Probes Included: LDO10105
- Protection Class: IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external
- Sensor A: LDO10105
- Sensor B: None
- Sensor C: None
- Storage Conditions: -20 – 60 °C, max. 90% relative humidity (non-condensing)
- Temperature Compensation: Automatic Temperature compensation for pH
- Temperature Measurement: °C or °F
- Temperature Resolution: 0.1 °C
- Type of Measurement: Field Measurements
- Warranty: 12 months
- Weight: 519 g (Meter only)
What’s Included?
- LEV015.53.1130A: HQ1130 Portable DO Meter, 1 channel
- LDO10105: IntelliCAL dissolved oxygen (DO) sensor, 5 m cable
- LEZ015.99.A002A: HQ rugged electrode field case
- LEZ015.99A003A: HQ hand strap & kickstand
- LEZ015.99.A004A: HQ protective glove
- 5828610: Cable marker for rugged electrode
- User Manuals: Included