Hanna HI718-25 Iodine Checker HC Reagents – 25 Tests DPD Method
The Hanna HI718-25 reagent set contains 25 high-quality, pre-measured packets specifically designed for use with the HI718 Iodine Checker HC. These reagents utilize the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method, in which iodine reacts with the reagent to produce a pink tint. The Checker HC measures the intensity of this color to determine iodine concentration in ppm (mg/L).
Each packet is clearly marked with a lot number and expiry date to ensure full traceability, quality control, and reliability—ideal for drinking water analysis, disinfection monitoring, and water quality testing in both lab and field settings.
Features
Pre-Measured for Accuracy: Each sachet contains the exact amount of reagent needed for a single test, reducing user error.
Fast & Reliable Readings: Designed to deliver accurate iodine measurements in under a minute using the HI718 Checker®.
Trusted DPD Method: Based on the proven DPD colorimetric method for iodine detection.
Traceable & High Purity: Reagents are manufactured in a temperature-controlled environment using reagent-grade chemicals.
Long Shelf Life: Clearly labeled with expiration date and lot number for quality assurance.
Specifications
Package Type: Powder sachets
Quantity: 25 tests per box
Method: DPD Colorimetric Method
Measurement Range (via Checker): 0.0 to 12.5 ppm (mg/L) iodine
Compatibility: Hanna HI718 Iodine Checker® HC
Shelf Life: Long-lasting when stored in a cool, dry environment
Applications
Drinking Water Monitoring: Measure iodine levels for disinfection control and safety.
Environmental Testing: Evaluate iodine presence in surface water and treated water.
Industrial Water Systems: Monitor iodine disinfection in cooling towers or water treatment systems.
Food & Beverage Processing: Ensure iodine-treated water remains within acceptable limits.
Laboratory & Educational Use: Great for academic demonstrations and controlled experiments.
Best Practice Tips for Accurate Results
Ensure the sample is free of debris before testing.
Wipe the outside of the cuvette thoroughly with a lint-free cloth (e.g., HI-731318) to remove fingerprints or oil.
Avoid bubbles: Do not shake the cuvette; gently swirl or tap to remove air bubbles.
Take readings immediately after the reaction—delays may compromise accuracy.
Discard the reacted sample immediately after testing to avoid staining the cuvette.