Hanna HI718-25 Iodine DPD method reagents

Rp123

Tanyakan Harga dan Stok Produk Terlebih Dahulu Melalui Whatsapp / Email Kami!

Hanna HI718-25 Iodine Checker HC Reagents – 25 Tests DPD Method

The Hanna HI718-25 reagent set contains 25 high-quality, pre-measured packets specifically designed for use with the HI718 Iodine Checker HC. These reagents utilize the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method, in which iodine reacts with the reagent to produce a pink tint. The Checker HC measures the intensity of this color to determine iodine concentration in ppm (mg/L).

Each packet is clearly marked with a lot number and expiry date to ensure full traceability, quality control, and reliability—ideal for drinking water analysis, disinfection monitoring, and water quality testing in both lab and field settings.

Features

  • Pre-Measured for Accuracy: Each sachet contains the exact amount of reagent needed for a single test, reducing user error.

  • Fast & Reliable Readings: Designed to deliver accurate iodine measurements in under a minute using the HI718 Checker®.

  • Trusted DPD Method: Based on the proven DPD colorimetric method for iodine detection.

  • Traceable & High Purity: Reagents are manufactured in a temperature-controlled environment using reagent-grade chemicals.

  • Long Shelf Life: Clearly labeled with expiration date and lot number for quality assurance.

Specifications

  • Package Type: Powder sachets

  • Quantity: 25 tests per box

  • Method: DPD Colorimetric Method

  • Measurement Range (via Checker): 0.0 to 12.5 ppm (mg/L) iodine

  • Compatibility: Hanna HI718 Iodine Checker® HC

  • Shelf Life: Long-lasting when stored in a cool, dry environment

Applications

  • Drinking Water Monitoring: Measure iodine levels for disinfection control and safety.

  • Environmental Testing: Evaluate iodine presence in surface water and treated water.

  • Industrial Water Systems: Monitor iodine disinfection in cooling towers or water treatment systems.

  • Food & Beverage Processing: Ensure iodine-treated water remains within acceptable limits.

  • Laboratory & Educational Use: Great for academic demonstrations and controlled experiments.

Best Practice Tips for Accurate Results

  • Ensure the sample is free of debris before testing.

  • Wipe the outside of the cuvette thoroughly with a lint-free cloth (e.g., HI-731318) to remove fingerprints or oil.

  • Avoid bubbles: Do not shake the cuvette; gently swirl or tap to remove air bubbles.

  • Take readings immediately after the reaction—delays may compromise accuracy.

  • Discard the reacted sample immediately after testing to avoid staining the cuvette.

Reviews

There are no reviews yet.

Be the first to review “Hanna HI718-25 Iodine DPD method reagents”