Horiba LAQUA EC220-K Conductivity / TDS / Salinity / Resistivity Meter
The Horiba LAQUA EC220-K – EC, TDS, Salinity, Resistivity helps users measure conductivity, TDS, resistivity, salinity, and temperature in field and laboratory environments. Moreover, this portable meter supports auto-ranging measurement, adjustable reference temperature, adjustable temperature coefficient, and flexible cell constant settings. In addition, the EC220-K provides 1000 data memory, auto data logging, real-time clock, date and time stamp, diagnostic messages, and electrode status display. Furthermore, the meter supports PC communication, printer communication, and software upgrade through compatible cables. As a result, this instrument works well for water quality testing, environmental monitoring, industrial process control, and routine laboratory analysis.
Key Features
Conductivity and TDS Measurement
The Horiba LAQUA EC220-K supports conductivity measurement up to 200.0 mS/cm with k = 1.0.
Moreover, the 0.05% full-scale resolution helps users obtain clear conductivity readings during routine testing.
In addition, the conductivity accuracy of ±0.6% full scale supports reliable measurement for general water quality analysis.
Furthermore, the meter supports selectable and auto-ranging units in S/cm and S/m, making measurement more flexible across different sample levels.
Also, the adjustable reference temperature from 15 to 30°C helps users match measurement conditions with laboratory requirements.
Meanwhile, the adjustable temperature coefficient from 0.00 to 10.00% improves flexibility for different sample types.
Additionally, the TDS function supports measurement up to 100 ppt with a TDS factor of 0.5.
Moreover, the TDS curves include Linear, EN27888, 442, and NaCl, so users can select the suitable conversion method.
Resistivity and Salinity Measurement
The EC220-K also supports resistivity measurement from 0.000 Ω·cm to 20.0 MΩ·cm.
Moreover, the resistivity function helps users monitor purified water, low-conductivity samples, and high-resistance water quality.
In addition, the salinity range from 0.0 to 100.0 ppt or 0.00 to 10.00% supports saltwater and process water testing.
Furthermore, the salinity curves include NaCl and seawater, allowing users to match the measurement method with the sample type.
Therefore, users can apply the EC220-K for conductivity-based water quality evaluation in various testing conditions.
Data Management and Communication
The meter provides 1000 data memory for storing and reviewing measurement results.
Moreover, auto data logging helps users collect measurement data more efficiently during repeated testing.
In addition, the real-time clock and date-time stamp support better traceability for laboratory documentation.
Furthermore, PC communication through the USB cable PN 3200779639 helps users transfer data for reporting and record management.
Also, printer communication through the RS232 cable PN 3200779638 helps users print measurement results when needed.
Additionally, the software upgrade function through PC connection helps users maintain the instrument system more easily.
Operation and Durability
The EC220-K supports up to 4 automatic calibration points and up to 5 manual calibration points.
Moreover, Auto Stable, Auto Hold, and Real-Time measurement modes give users flexible operation for different sample conditions.
In addition, the on-screen electrode status helps users monitor electrode condition during measurement.
Furthermore, diagnostic messages help users identify measurement issues more quickly.
Meanwhile, the custom LCD with backlight helps users view readings clearly in indoor and outdoor environments.
Finally, the IP67 housing, shock-resistant body, scratch-resistant surface, and non-slip design improve durability during field use.
Specifications
General Information
Product Name: Horiba LAQUA EC220-K Conductivity / TDS / Salinity / Resistivity Meter
Model: LAQUA EC220-K
Product Type: Portable conductivity, TDS, resistivity, salinity, and temperature meter
Conductivity Specifications
Conductivity Range: Up to 200.0 mS/cm with k = 1.0
Conductivity Resolution: 0.05% full scale
Conductivity Accuracy: ±0.6% full scale; ±1.5% full scale above 18.0 mS/cm
Reference Temperature: 15 to 30°C, adjustable
Temperature Coefficient: 0.00 to 10.00%, adjustable
Cell Constant: 0.1, 1.0, 10.0, adjustable
Calibration Points: Up to 4 automatic points or up to 5 manual points
Measurement Unit: S/cm and S/m, selectable and auto-ranging
TDS, Resistivity, and Salinity Specifications
TDS Range: Up to 100 ppt with TDS factor = 0.5
TDS Resolution: 0.01 ppm or mg/L; 0.1 ppt or g/L
TDS Accuracy: ±0.1% full scale
TDS Curves: Linear 0.40 to 1.00, EN27888, 442, NaCl
Resistivity Range: 0.000 Ω·cm to 20.0 MΩ·cm
Resistivity Resolution: 0.05% full scale
Resistivity Accuracy: ±0.6% full scale; ±1.5% full scale above 18.0 MΩ·cm
Salinity Range: 0.0 to 100.0 ppt; 0.00 to 10.00%
Salinity Resolution: 0.1 ppt; 0.01%
Salinity Accuracy: ±0.2% full scale
Salinity Curves: NaCl and seawater
Salinity Calibration Option: Yes
Temperature and System Specifications
Temperature Range: -30.0 to 130.0°C; -22.0 to 266.0°F
Temperature Resolution: 0.1°C / °F
Temperature Accuracy: ±0.5°C / ±0.9°F
Temperature Calibration Option: Yes
Memory Data: 1000 data sets
Auto Log Data: Yes
Real-Time Clock: Yes
Date and Time Stamp: Yes
Measurement Modes: Auto Stable, Auto Hold, Real Time
Auto Shut-Off: Yes, programmable up to 30 minutes
Electrode Status: Yes, on-screen display
Diagnostic Messages: Yes
Software Upgrade: Yes, via PC USB cable PN 3200779639
PC Communication: Yes, via PC USB cable PN 3200779639
Printer Communication: Yes, via printer RS232 cable PN 3200779638
Meter Inputs: BNC for conductivity electrode, phono for temperature sensor
Meter Output: Phono for PC or printer connection
Display: Custom LCD with backlight
Housing: IP67, shock-resistant, scratch-resistant, and non-slip
Power Requirement: 2 × AA batteries
Battery Life: More than 500 hours
Meter Dimensions: 160 × 80 × 40.60 mm
Meter Weight: Approximately 260 g with batteries; 216 g without batteries
Applications
Water Quality Testing
Horiba LAQUA EC220-K Conductivity / TDS / Salinity / Resistivity Meter supports water quality testing in laboratories, field monitoring, environmental inspection, and industrial quality control.
Moreover, users can apply this meter to analyze surface water, groundwater, wastewater, treated water, process water, cooling water, and boiler water.
In addition, the conductivity and TDS functions help users evaluate dissolved ion levels and general water quality conditions.
Furthermore, the resistivity function supports purified water checking and low-conductivity water monitoring.
Field and Industrial Use
The IP67 housing makes the EC220-K suitable for field testing and demanding work environments.
Moreover, environmental teams can use this meter for salinity monitoring, conductivity surveys, and routine water inspection.
In addition, industrial users can use the instrument to monitor production water, cleaning water, treatment systems, and process control samples.
Meanwhile, laboratory teams can use the memory, date-time stamp, PC communication, and printer communication features to organize records more efficiently.
Therefore, the wide measurement capability, durable housing, long battery life, auto data logging, and communication functions make the LAQUA EC220-K suitable for users who need a reliable portable meter for conductivity-based water analysis.
Order Information
Please contact us via WhatsApp or email to check the latest price and product stock before ordering.
Tags
You must be logged in to post a review.






Reviews
There are no reviews yet.