SONDELTOX Duran Electronica detectors for toxic gases

Rp123

Tanyakan Harga dan Stok Produk Terlebih Dahulu Melalui Whatsapp / Email Kami!

SONDELTOX Duran Electronica 4-20mA detectors for toxic gases & O2

Available Gas Detectors:

  • Carbon Monoxide (CO)
  • Nitrogen Dioxide (NO2)
  • Sulphur Dioxide (SO2)
  • Nitrogen Monoxide (NO)
  • Hydrogen Sulphide (H2S)
  • Chlorine (Cl2)
  • Oxygen (O2)
  • Hydrogen (H2)

 

SONDELTOX Duran Electronica 4-20mA detectors for toxic gases & O2 Technical Characteristics

CharacteristicCONO2SO2NOH2SO2Cl2H2
Power Supply / Consumption10 to 35V DC / 21mA max.24 to 35 VDC display model24 to 35 VDC display model24 to 35 VDC display model24 to 35 VDC display model24 to 35 VDC display model24 to 35 VDC display model24 to 35 VDC display model
Resolution≤5 ppm≤0.5 ppm≤1 ppm≤0.5 ppm≤0.25 ppm≤0.1%≤0.1 ppm≤0.15%
Measurement Range0-300 ppm0-20 ppm0-200 ppm0-100 ppm0-200 ppm0-25%0-10 ppm0-5%
Repeatability1% F.S.2% F.S.2% F.S.2% F.S.1% F.S.1% F.S.2% F.S.2% F.S.
Time of ResponseT90 < 30sT90 < 35sT90 < 15sT90 < 10sT90 < 35sT90 < 15sT90 < 60sT90 < 30s
Temperature Range-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC-20ºC to +50ºC
Pressure RangeAtmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%Atmospheric ± 10%
Pressure Coefficient0.020 ± 0.008% signal/mBar0.016% signal/mBar0.008 ± 0.002% signal/mBar0.02% signal/mBar0.009 ± 0.003% signal/mBarWithout dataWithout dataWithout data
EnclosureIP65IP65IP65IP65IP65IP65IP65IP65
Relative Humidity Range15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation15 to 90% without condensation
Maximum Zero Change (+20ºC to +40ºC)3 ppm0.3 ppm0.1 ppm1 ppm2 ppm3%0.2 ppm10 ppm
Output LinearityLinear in full rangeLinear in full rangeLinear in full rangeLinear in full rangeLinear in full rangeLinear in full rangeLinear in full rangeLinear in full range
Output Drift<5% / year<2% / month<2% / month<2% / month<2% / month<5% / year<2% / month<2% / month
Output Impedance4MΩ4MΩ4MΩ4MΩ4MΩ15MΩ4MΩ4MΩ
Expected Operation Life3 years on air2 years on air2 years on air3 years on air2 years on air2 years at 20% O22 years on air2 years on air
Storage Time (months)66666266
Storage Temperature0-50ºC0-50ºC0-50ºC0-50ºC0-50ºC0-50ºC0-50ºC0-50ºC
Coverage Area (m²)Approx. 200Approx. 100Approx. 200Approx. 150Approx. 150Approx. 200Approx. 100Approx. 100
Installation Height (cm from floor)150-20040/5030/40100100170-20010030/40 (from ceiling)
Dimensions (mm)125 x 150 x 63125 x 150 x 63125 x 150 x 63125 x 150 x 63125 x 150 x 63125 x 150 x 63125 x 150 x 63125 x 150 x 63
Weight (g)Approx. 300Approx. 300Approx. 300Approx. 300Approx. 300Approx. 300Approx. 300Approx. 300

Reviews

There are no reviews yet.

Be the first to review “SONDELTOX Duran Electronica detectors for toxic gases”