Cannon 9721-F68 CFOC- 300 Calibrated
This Cannon 9721-F68 CFOC- 300 Calibrated kinematic viscosity of dark Newtonian liquids. It uses a reverse-flow design for reliable readings. Therefore, it performs well when the meniscus is not visible. As a result, it removes limits of routine Cannon-Fenske viscometers.
Moreover, this instrument follows ASTM D445 and ISO 3104. In addition, it conforms to ASTM D446 and ISO 3105. Consequently, laboratories can apply it in standardized viscosity testing.
Furthermore, this model supports asphalt and road oil testing at 60 °C (140 °F). It follows ASTM D2170. Thus, it suits petroleum and materials laboratories. Additionally, researchers use it for lubricating and hydraulic oils at low temperatures. In particular, it helps study additive effects.
Notably, users can apply external pressure. Therefore, they may vary shear stress and shear rate. Meanwhile, factory calibration at 40 °C ensures traceable results.
Finally, this viscometer integrates with constant-temperature baths. Moreover, optional holders provide stable positioning. As a result, measurements remain consistent.
Product Features
Measures viscosity of dark Newtonian liquids
Uses reverse-flow design for opaque samples
Therefore improves accuracy without visible meniscus
Calibrated at 40 °C with certificate and instructions
Complies with ASTM D445 and ISO 3104
Additionally conforms to ASTM D446 and ISO 3105
Supports asphalt testing per ASTM D2170
Moreover suitable for low-temperature lubricant studies
Allows external pressure for shear control
Special constants available on request
Compatible with constant-temperature baths
Optional holders ensure stable mounting
Specifications
Model: 9721-F68 CFOC-300
Instrument Type: Cannon-Fenske Opaque Reverse-Flow Viscometer
Manufacturer: Cannon Instruments
Measurement Method: Kinematic viscosity by gravity flow
Standards: ASTM D445, ISO 3104
Additional Standards: ASTM D446, ISO 3105
Asphalt Method: ASTM D2170
Calibration Temperature: 40 °C
Approximate Constant: 0.25 cSt/s
Viscosity Range: 50 to 250 cSt
Flow Time Range: 200 to 1,000 seconds
Minimum Sample Volume: 12 mL
Minimum Bath Depth: 229 mm (9 inches)
Calibration Status: Calibrated
Compatible Holders: 9726-M50 and 9726-M53
Replacement Micro Stoppers: 9726-N98
Sample Type: Dark Newtonian liquids
Applications
Cutback asphalt viscosity testing
Road oil quality control
Petroleum and heavy oil analysis
Low-temperature lubricant evaluation
Hydraulic oil additive studies
Research and industrial laboratories