Cannon 9722-H50 Ubbelohde 25 Semi-Micro Calibrated
The Cannon 9722-H50 Ubbelohde 25 Semi-Micro Calibrated is specifically developed for highly precise measurement of kinematic viscosity in small volumes of transparent Newtonian liquids. It complies with ASTM D445 and ISO 3104 standards; therefore, laboratories can confidently perform viscosity testing according to internationally recognized procedures. Moreover, its semi-micro design significantly reduces sample consumption while maintaining excellent analytical accuracy.
In addition, the suspended-level Ubbelohde design ensures that the viscometer constant remains independent of liquid head pressure. As a result, measurements remain stable and reproducible across repeated tests. Furthermore, because the viscometer constant is the same at all temperatures, laboratories benefit from simplified calculations and consistent performance.
Features
First, the instrument accurately measures low-range kinematic viscosity from 0.4 to 2 cSt.
Moreover, it requires only approximately 1 mL of sample, which is ideal for limited or high-value materials.
In addition, it supports intrinsic viscosity determination with dilution up to 20 mL, making it suitable for polymer solution analysis.
Furthermore, it is fully calibrated and supplied with a certificate of calibration and instruction sheet for traceable measurement results.
At the same time, its precision borosilicate glass construction ensures excellent chemical resistance and long-term durability.
Finally, the constant remains identical at all temperatures, improving testing convenience and reliability.
Specifications
Model: 9722-H50
Type: Ubbelohde Semi-Micro, Suspended-Level
Calibration Status: Calibrated (with certificate)
Minimum Sample Volume: Approximately 1 mL
Maximum Dilution Volume for Intrinsic Viscosity: Up to 20 mL
Minimum Bath Depth Required: 240 mm (9.5 inches)
Viscometer Constant: Approximately 0.002 cSt/s
Viscosity Range: 0.4 to 2 cSt
Applicable Standards: ASTM D445, ISO 3104
Material: Precision borosilicate glass
Holder Compatibility: 9726-M70, 9726-M73, 9726-M76 (sold separately)
Applications
Primarily, this viscometer is used for low-viscosity liquid analysis such as light hydrocarbons, solvents, and refined petroleum products. Additionally, it supports polymer research, especially for intrinsic viscosity studies of dilute solutions. Likewise, academic laboratories and industrial quality control departments rely on this model for precise and traceable viscosity measurements. Because of its low viscosity range and minimal sample requirement, it is particularly suitable for sensitive laboratory applications.