Horiba U-53G-10 Multi-Parameter Water Quality Meter

Rp123

Tanyakan Harga dan Stok Produk Terlebih Dahulu Melalui Whatsapp / Email Kami!

Horiba U-53G-10 Multi-Parameter Water Quality Meter

The Horiba U-53G-10 Multi-Parameter Water Quality Meter helps users measure several important water quality parameters directly in the field. Moreover, this model comes with a 10 m cable and GPS support, making it suitable for deeper sampling points and location-based water quality monitoring. In addition, the U-53G-10 supports pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature measurement in one portable system. Furthermore, the U-53G turbidity sensor conforms to US EPA Method 180.1, so users can apply it for field turbidity monitoring that requires this measurement approach. As a result, this meter works well for environmental monitoring, wastewater inspection, water treatment control, industrial water testing, and routine field analysis.

Key Features

Multiparameter Field Measurement
  • The Horiba U-53G-10 supports multiple water quality parameters in one portable field instrument.
  • Moreover, users can measure pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature with one sensor probe.
  • In addition, the 10 m cable helps users measure water quality at deeper or harder-to-reach sampling points.
  • Furthermore, the meter reduces the need for several separate instruments during field inspection.
  • Therefore, users can collect complete water quality data more efficiently during outdoor monitoring.
GPS and Location-Based Monitoring
  • The U-53G-10 includes GPS support for field measurement location tracking.
  • Moreover, GPS support helps users connect water quality data with sampling locations during environmental surveys.
  • In addition, this function helps teams organize monitoring data from rivers, lakes, ponds, coastal areas, reservoirs, and treatment sites.
  • Furthermore, location-based records support better documentation for long-term water quality programs.
  • As a result, users can manage field measurement data more clearly and trace each reading to its sampling point.
EPA Method 180.1 Turbidity Measurement
  • The U-53G-10 includes turbidity measurement with a tungsten lamp source and 90° scattering method.
  • Moreover, the turbidity range from 0 to 1000 NTU supports testing in surface water, treated water, wastewater, and environmental samples.
  • In addition, the low-range turbidity resolution helps users observe small changes in water clarity.
  • Furthermore, the turbidity sensor conforms to US EPA Method 180.1, making it suitable for applications that require this turbidity measurement standard.
  • Therefore, users can monitor turbidity, suspended particles, and water clarity directly in the field.
Water Depth and Field Operation
  • The 10 m cable version supports water depth measurement with a pressure method.
  • Moreover, the 0 to 30 m water depth range helps users document sampling depth during field monitoring.
  • In addition, the 0.05 m water depth resolution supports practical depth recording during site inspection.
  • Furthermore, the 10 m cable gives users more flexibility when testing water at deeper sampling locations.
  • Therefore, the U-53G-10 helps users record water quality parameters, sampling depth, and location data in one field workflow.

Specifications

General Information
  • Product Name: Horiba U-53G-10 Multi-Parameter Water Quality Meter
  • Model: U-53G-10
  • Model Code: 3200164504
  • Product Type: Portable multi-parameter water quality meter with GPS
  • Cable Length: 10 m
  • Measured Parameters: pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature
  • GPS: Included
Sensor Probe Specifications
  • Measurement Temperature: -10 to 55°C
  • Maximum Sensor Diameter: Approximately 96 mm
  • Probe Length: Approximately 340 mm
  • Sensor Probe Mass: Approximately 1,800 g
  • Measurement Depth: Max. 30 m
  • Sensor Probe Water Resistance: JIS protection level 8
  • Cable Length: 10 m
Control Unit Specifications
  • Outer Dimensions: 115 × 66 × 335 mm for control unit with GPS
  • Control Unit Mass: Approximately 800 g
  • Display: 320 × 240 liquid crystal display with backlight
  • Data Memory: 10,000 data sets
  • Communication: USB
  • Battery: 4 × C batteries
  • Control Unit Water Resistance: JIS protection level 7 when sensor cable is fitted
  • Battery Life: Approximately 70 hours without backlight
  • Storage Temperature: -10 to 60°C
  • Ambient Temperature: -5 to 45°C
pH Specifications
  • Measurement Principle: Glass electrode method
  • pH Range: 0 to 14 pH
  • pH Resolution: 0.01 pH
  • pH Repeatability: ±0.05 pH
  • pH Accuracy: ±0.1 pH
ORP Specifications
  • Measurement Principle: Platinum electrode method
  • ORP Range: -2000 mV to +2000 mV
  • ORP Resolution: 1 mV
  • ORP Repeatability: ±5 mV
  • ORP Accuracy: ±15 mV
Dissolved Oxygen Specifications
  • Measurement Principle: Polarographic method
  • DO Range: 0 to 50.0 mg/L
  • DO Resolution: 0.01 mg/L
  • DO Repeatability: ±0.1 mg/L
  • DO Accuracy: ±0.2 mg/L from 0 to 20 mg/L; ±0.5 mg/L from 20 to 50 mg/L
Conductivity Specifications
  • Measurement Principle: 4 AC electrode method
  • Conductivity Range: 0 to 10 S/m or 0 to 100 mS/cm
  • Conductivity Resolution: 0.001 mS/cm from 0.000 to 0.999 mS/cm; 0.01 mS/cm from 1.00 to 9.99 mS/cm; 0.1 mS/cm from 10.0 to 99.9 mS/cm
  • Conductivity Repeatability: ±0.5% full scale
  • Conductivity Accuracy: ±1% full scale
Salinity, TDS, and Seawater Specific Gravity
  • Salinity Measurement Principle: Conductivity conversion
  • Salinity Range: 0 to 70 PPT
  • Salinity Resolution: 0.1 PPT
  • Salinity Repeatability: ±1 PPT
  • Salinity Accuracy: ±3 PPT
  • TDS Measurement Principle: Conductivity conversion
  • TDS Range: 0 to 100 g/L
  • TDS Resolution: 0.1% full scale
  • TDS Repeatability: ±2 g/L
  • TDS Accuracy: ±5 g/L
  • Seawater Specific Gravity Measurement Principle: Conductivity conversion
  • Seawater Specific Gravity Range: 0 to 50 σt
  • Seawater Specific Gravity Resolution: 0.1 σt
  • Seawater Specific Gravity Repeatability: ±2 σt
  • Seawater Specific Gravity Accuracy: ±5 σt
Turbidity and Water Depth Specifications
  • Turbidity Measurement Principle: Tungsten lamp source and 90° scattering method
  • Turbidity Standard: Conforms to US EPA Method 180.1
  • Turbidity Range: 0 to 1000 NTU
  • Turbidity Resolution: 0.01 NTU from 0 to 9.99 NTU; 0.1 NTU from 10 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
  • Turbidity Repeatability: ±3% of reading or ±0.1 NTU, whichever is greater
  • Turbidity Accuracy: ±0.5 NTU from 0 to 10 NTU; ±3% of reading or ±1 NTU from 10 to 1000 NTU
  • Water Depth Measurement Principle: Pressure method
  • Water Depth Range: 0 to 30 m
  • Water Depth Resolution: 0.05 m
  • Water Depth Repeatability: ±1% full scale
  • Water Depth Accuracy: ±0.3 m
Temperature Specifications
  • Measurement Principle: Thermistor method
  • Temperature Range: -10 to 55°C
  • Temperature Resolution: 0.01°C
  • Temperature Repeatability: ±0.10°C at calibration point
  • Temperature Accuracy: JIS Class B thermistor sensor, ±(0.3 + 0.005|t|)

Applications

Environmental Water Monitoring
  • Horiba U-53G-10 Multi-Parameter Water Quality Meter supports field monitoring in rivers, lakes, ponds, reservoirs, groundwater, drainage channels, wastewater areas, and treatment facilities.
  • Moreover, environmental teams can use this meter to check pH, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature during site inspection.
  • In addition, GPS support helps users connect measurement data with sampling locations for better field documentation.
  • Furthermore, the 10 m cable helps users perform practical testing at deeper sampling points and wider monitoring locations.
Water Treatment and Industrial Testing
  • Water treatment facilities can use the U-53G-10 to monitor incoming water, treated water, process water, and discharge water.
  • Moreover, industrial users can apply this meter for routine checking in production water, cooling water, wastewater treatment systems, and environmental compliance workflows.
  • In addition, laboratories can use the meter for sample verification before or after field collection.
  • Meanwhile, the EPA Method 180.1 turbidity sensor helps users evaluate water clarity and suspended solids conditions during routine monitoring.
  • Therefore, the multiparameter measurement capability, GPS support, 10 m cable, EPA Method 180.1 turbidity function, water depth support, rugged probe design, backlit LCD, high data memory, and water-resistant construction make the Horiba U-53G-10 suitable for professional field water quality monitoring.