Horiba U-53G-10 Multi-Parameter Water Quality Meter
The Horiba U-53G-10 Multi-Parameter Water Quality Meter helps users measure several important water quality parameters directly in the field. Moreover, this model comes with a 10 m cable and GPS support, making it suitable for deeper sampling points and location-based water quality monitoring. In addition, the U-53G-10 supports pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature measurement in one portable system. Furthermore, the U-53G turbidity sensor conforms to US EPA Method 180.1, so users can apply it for field turbidity monitoring that requires this measurement approach. As a result, this meter works well for environmental monitoring, wastewater inspection, water treatment control, industrial water testing, and routine field analysis.
Key Features
Multiparameter Field Measurement
- The Horiba U-53G-10 supports multiple water quality parameters in one portable field instrument.
- Moreover, users can measure pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature with one sensor probe.
- In addition, the 10 m cable helps users measure water quality at deeper or harder-to-reach sampling points.
- Furthermore, the meter reduces the need for several separate instruments during field inspection.
- Therefore, users can collect complete water quality data more efficiently during outdoor monitoring.
GPS and Location-Based Monitoring
- The U-53G-10 includes GPS support for field measurement location tracking.
- Moreover, GPS support helps users connect water quality data with sampling locations during environmental surveys.
- In addition, this function helps teams organize monitoring data from rivers, lakes, ponds, coastal areas, reservoirs, and treatment sites.
- Furthermore, location-based records support better documentation for long-term water quality programs.
- As a result, users can manage field measurement data more clearly and trace each reading to its sampling point.
EPA Method 180.1 Turbidity Measurement
- The U-53G-10 includes turbidity measurement with a tungsten lamp source and 90° scattering method.
- Moreover, the turbidity range from 0 to 1000 NTU supports testing in surface water, treated water, wastewater, and environmental samples.
- In addition, the low-range turbidity resolution helps users observe small changes in water clarity.
- Furthermore, the turbidity sensor conforms to US EPA Method 180.1, making it suitable for applications that require this turbidity measurement standard.
- Therefore, users can monitor turbidity, suspended particles, and water clarity directly in the field.
Water Depth and Field Operation
- The 10 m cable version supports water depth measurement with a pressure method.
- Moreover, the 0 to 30 m water depth range helps users document sampling depth during field monitoring.
- In addition, the 0.05 m water depth resolution supports practical depth recording during site inspection.
- Furthermore, the 10 m cable gives users more flexibility when testing water at deeper sampling locations.
- Therefore, the U-53G-10 helps users record water quality parameters, sampling depth, and location data in one field workflow.
Specifications
General Information
- Product Name: Horiba U-53G-10 Multi-Parameter Water Quality Meter
- Model: U-53G-10
- Model Code: 3200164504
- Product Type: Portable multi-parameter water quality meter with GPS
- Cable Length: 10 m
- Measured Parameters: pH, pHmV, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature
- GPS: Included
Sensor Probe Specifications
- Measurement Temperature: -10 to 55°C
- Maximum Sensor Diameter: Approximately 96 mm
- Probe Length: Approximately 340 mm
- Sensor Probe Mass: Approximately 1,800 g
- Measurement Depth: Max. 30 m
- Sensor Probe Water Resistance: JIS protection level 8
- Cable Length: 10 m
Control Unit Specifications
- Outer Dimensions: 115 × 66 × 335 mm for control unit with GPS
- Control Unit Mass: Approximately 800 g
- Display: 320 × 240 liquid crystal display with backlight
- Data Memory: 10,000 data sets
- Communication: USB
- Battery: 4 × C batteries
- Control Unit Water Resistance: JIS protection level 7 when sensor cable is fitted
- Battery Life: Approximately 70 hours without backlight
- Storage Temperature: -10 to 60°C
- Ambient Temperature: -5 to 45°C
pH Specifications
- Measurement Principle: Glass electrode method
- pH Range: 0 to 14 pH
- pH Resolution: 0.01 pH
- pH Repeatability: ±0.05 pH
- pH Accuracy: ±0.1 pH
ORP Specifications
- Measurement Principle: Platinum electrode method
- ORP Range: -2000 mV to +2000 mV
- ORP Resolution: 1 mV
- ORP Repeatability: ±5 mV
- ORP Accuracy: ±15 mV
Dissolved Oxygen Specifications
- Measurement Principle: Polarographic method
- DO Range: 0 to 50.0 mg/L
- DO Resolution: 0.01 mg/L
- DO Repeatability: ±0.1 mg/L
- DO Accuracy: ±0.2 mg/L from 0 to 20 mg/L; ±0.5 mg/L from 20 to 50 mg/L
Conductivity Specifications
- Measurement Principle: 4 AC electrode method
- Conductivity Range: 0 to 10 S/m or 0 to 100 mS/cm
- Conductivity Resolution: 0.001 mS/cm from 0.000 to 0.999 mS/cm; 0.01 mS/cm from 1.00 to 9.99 mS/cm; 0.1 mS/cm from 10.0 to 99.9 mS/cm
- Conductivity Repeatability: ±0.5% full scale
- Conductivity Accuracy: ±1% full scale
Salinity, TDS, and Seawater Specific Gravity
- Salinity Measurement Principle: Conductivity conversion
- Salinity Range: 0 to 70 PPT
- Salinity Resolution: 0.1 PPT
- Salinity Repeatability: ±1 PPT
- Salinity Accuracy: ±3 PPT
- TDS Measurement Principle: Conductivity conversion
- TDS Range: 0 to 100 g/L
- TDS Resolution: 0.1% full scale
- TDS Repeatability: ±2 g/L
- TDS Accuracy: ±5 g/L
- Seawater Specific Gravity Measurement Principle: Conductivity conversion
- Seawater Specific Gravity Range: 0 to 50 σt
- Seawater Specific Gravity Resolution: 0.1 σt
- Seawater Specific Gravity Repeatability: ±2 σt
- Seawater Specific Gravity Accuracy: ±5 σt
Turbidity and Water Depth Specifications
- Turbidity Measurement Principle: Tungsten lamp source and 90° scattering method
- Turbidity Standard: Conforms to US EPA Method 180.1
- Turbidity Range: 0 to 1000 NTU
- Turbidity Resolution: 0.01 NTU from 0 to 9.99 NTU; 0.1 NTU from 10 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
- Turbidity Repeatability: ±3% of reading or ±0.1 NTU, whichever is greater
- Turbidity Accuracy: ±0.5 NTU from 0 to 10 NTU; ±3% of reading or ±1 NTU from 10 to 1000 NTU
- Water Depth Measurement Principle: Pressure method
- Water Depth Range: 0 to 30 m
- Water Depth Resolution: 0.05 m
- Water Depth Repeatability: ±1% full scale
- Water Depth Accuracy: ±0.3 m
Temperature Specifications
- Measurement Principle: Thermistor method
- Temperature Range: -10 to 55°C
- Temperature Resolution: 0.01°C
- Temperature Repeatability: ±0.10°C at calibration point
- Temperature Accuracy: JIS Class B thermistor sensor, ±(0.3 + 0.005|t|)
Applications
Environmental Water Monitoring
- Horiba U-53G-10 Multi-Parameter Water Quality Meter supports field monitoring in rivers, lakes, ponds, reservoirs, groundwater, drainage channels, wastewater areas, and treatment facilities.
- Moreover, environmental teams can use this meter to check pH, ORP, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, water depth, and temperature during site inspection.
- In addition, GPS support helps users connect measurement data with sampling locations for better field documentation.
- Furthermore, the 10 m cable helps users perform practical testing at deeper sampling points and wider monitoring locations.
Water Treatment and Industrial Testing
- Water treatment facilities can use the U-53G-10 to monitor incoming water, treated water, process water, and discharge water.
- Moreover, industrial users can apply this meter for routine checking in production water, cooling water, wastewater treatment systems, and environmental compliance workflows.
- In addition, laboratories can use the meter for sample verification before or after field collection.
- Meanwhile, the EPA Method 180.1 turbidity sensor helps users evaluate water clarity and suspended solids conditions during routine monitoring.
- Therefore, the multiparameter measurement capability, GPS support, 10 m cable, EPA Method 180.1 turbidity function, water depth support, rugged probe design, backlit LCD, high data memory, and water-resistant construction make the Horiba U-53G-10 suitable for professional field water quality monitoring.
You must be logged in to post a review.






Reviews