Micro balance AND LCCA21N100
The Micro balance AND LCCA21N100 is a compression-type load cell equipped with a built-in analog amplifier, optimized for load distribution and press pressure measurement. With a rated capacity of 100 N (10.2 kg) and factory-calibrated voltage output, it is ideal for precise, low-force applications requiring compact design, quick integration, and stable analog signal output.
This model includes both a standard attachment holder and an amplifier case holder, simplifying installation in OEM equipment, test rigs, or automation systems.
Key Features
Compression Type Force Sensor
Designed for accurate vertical force measurement, particularly in confined spaces where button-style sensors are required.Integrated Analog Amplifier
Outputs a clean 1 to 4 V analog voltage range, allowing direct connection to analog input modules (no need for separate signal conditioning).Rated Capacity:
100 N (10.2 kg) – suitable for low-force applications such as component testing, button pressure measurement, or robotic end-effector monitoring.Excellent Output Stability:
Span Voltage: 2 V ± 0.01 V (between 1–3 V output range)
Zero Voltage: 1 V ± 0.04 V
Load Resistance: ≥ 5 kΩ
Built-in Protection & Reliability:
Dust/water protection: IP64
Insulation resistance: ≥ 500 MΩ (DC 50 V between signal wires and cell)
Safe Load Limit: 150% of rated capacity
Temperature Performance:
Compensated Range: 0 to 70°C
Operation Range: –10 to 80°C
Temperature Effect (Zero/Span): 0.6% R.O. / 10°C (typical)
Frequency Response:
100 Hz (–3 dB) — suitable for dynamic measurements in moderate-speed applications.
Standard Accessories
1 Attachment Holder – For mounting the load cell to test fixtures or machines
1 Amplifier Case Holder Set – For secure housing and protection of the built-in amplifier
Cable Configuration
From Load Cell to Amplifier: Ø2 mm, 2 meters
From Amplifier to Output: Ø6 mm, 0.5 meters
Applications
Load Distribution Monitoring – Analyze how weight or force is distributed across surfaces or contact points
Press Force Measurement – Track real-time pressure changes in stamping, crimping, or forming operations
Switch & Button Testing – Evaluate actuation pressure for QA or development of keyboards, control panels, etc.
Component Force Testing – Precision measurement of applied force in small mechanical parts or medical devices
Embedded Robotic Sensing – Suitable for integration in robotic grippers or safety feedback loops
Technical Summary
| Parameter | Specification |
|---|---|
| Model | LCCA21N100 |
| Capacity | 100 N (10.2 kg) |
| Output Voltage Range | 1 – 4 V |
| Zero Voltage | 1 ± 0.04 V |
| Span Voltage | 2 ± 0.01 V (1 to 3 V range) |
| Load Resistance | ≥ 5 kΩ |
| Supply Voltage | 5 V DC ±0.25 V (< 16 mA) |
| Combined Error | ≤ 0.5% of Rated Output |
| Insulation Resistance | ≥ 500 MΩ (DC 50 V) |
| Dust/Water Protection | IP64 |
| Frequency Response | 100 Hz (–3 dB) |
| Temperature Range (Use/Compensated) | –10 to 80°C / 0 to 70°C |
| Standard Accessories | 1 attachment holder, 1 amplifier holder |
| Weight | 1.5 kg |