DS Meters for Measuring TDS/Conductivity

Rp123

Tanyakan Harga dan Stok Produk Terlebih Dahulu Melalui Whatsapp / Email Kami!

DS Meters for Measuring TDS/Conductivity Myron L

Overview

Reliable Measurements You Can Trust

No water source is entirely pure. Industrial, commercial, and natural sources all contain dissolved solids or salts, leading to scale formation, corrosion, unpleasant tastes, and environmental pollution that can harm plant and animal life.

Myron L® Company offers two reliable methods for detecting these impurities. Our DS Meters™ deliver quick and precise on-site measurements of total dissolved solids (TDS) or conductivity, while pDS Meters™ extend functionality by testing conductivity or TDS, as well as pH levels. These instruments, with their highly stable circuitry, ensure product quality, prevent equipment damage, and verify in-line instrumentation across various applications.

Built-in Reliability

Sensor failure in typical pH or conductivity instruments often results from breakage. Myron L® instruments are designed to maximize protection for both pH and conductivity electrodes within the cell cup. The pH electrode is user-replaceable and features a chemical-resistant, porous liquid junction for added durability.

Unique and Field-Tested Design

Our unique, robust, field-tested design has been perfected over more than 55 years, making Myron L® instruments some of the most trusted and widely used in the industry. Lightweight and compact, Myron L®’s DS and pDS Meters are also exceptionally durable, featuring rugged taut-band meter movements. Put our meters to the test, and even after years of demanding field service, they’ll exceed your expectations for accuracy, reliability, and ease of use.

Easy and Accurate Readings in 3 Simple Steps:

  1. Rinse and fill the cell cup.
  2. Select the appropriate Conductivity/TDS range.
  3. Push the button to display the reading.

DS Meters™ for Measuring pH/Conductivity and TDS

EP11/PH

  • Description: pDS pH/Conductivity Meter with measurement ranges of 0-10, 100, 1000, and 10,000 µM/µS, and pH range of 2-12.

T6/PH

  • Description: pDS pH/TDS Meter with measurement ranges of 0-5000 ppm and pH range of 2-12.

DS Meters for Measuring TDS/Conductivity Specifications

  • Ranges:
    • Conductivity: Varies by model, from 0-0.5 µM/µS to 0-10,000 µM/µS.
    • pH (for pDS Meters only): 2-12 pH.
  • Readout: 2½ in. taut-band shock-resistant meter.
  • Units of Measure: Choice of parts per million (ppm) TDS or micromhos (µM)/microsiemens (µS) conductivity.
  • Accuracy:
    • Conductivity: ±2% full scale.
    • pH: ±0.2 pH units.
  • Repeatability: ±1%.
  • Temperature Compensation: Automatic adjustment to 25°C/77°F for conductivity samples between 10-71°C/50-160°F.
  • Calibration Controls:
    • Conductivity: Adjustable.
    • pH: Adjustable for Zero and Gain.
  • Electrodes (built-in):
    • Conductivity: Never needs replatinizing.
    • pH: KCl gel-filled, field-replaceable.
  • Cell Cup: Made of chip and crack-resistant polyethylene.
  • Circuitry: Very stable, requiring minimal recalibration.
  • Power: One 9-volt battery (supplied), with a battery life of over 2000 tests or 1 year.
  • Dimensions: 3.4 W x 4.5 D x 4.0 H in. / 86 W x 114 D x 102 H mm.
  • Weight: 1 lb. / 0.45 kg.
  • Note: 1 µM (micromho) = 1 µS (microsiemen).

DS Meters for Measuring pH/Conductivity and TDS

EP11/PH

  • Description: pDS pH/Conductivity Meter with measurement ranges of 0-10, 100, 1000, and 10,000 µM/µS, and pH range of 2-12.

T6/PH

  • Description: pDS pH/TDS Meter with measurement ranges of 0-5000 ppm and pH range of 2-12.
512M5

DS Conductivity Meter with a measurement range of 0-5000 µM/µS.

512M10

DS Conductivity Meter with a measurement range of 0-10,000 µM/µS.

512T4

DS TDS Meter with a measurement range of 0-2500 ppm.

512T5

DS TDS Meter with a measurement range of 0-5000 ppm.

512T5D

POOLMETER™ DS TDS Meter, offering measurement ranges of 0-5000 ppm/442 and 0-5000 ppm/NaCl.

512T10

DS TDS Meter with a measurement range of 0-10,000 ppm.

532M1

DS Conductivity Meter with measurement ranges of 0-50, 500, and 5000 µM/µS.

532T1

DS TDS Meter with measurement ranges of 0-50, 500, and 5000 ppm.

532T2

DS TDS Meter with measurement ranges of 0-25, 250, and 2500 ppm.

AG-5

AGRI-METER™ DS Conductivity Meter with a measurement range of 0-5 millimhos.

D-1

DIALYSATE METER™ DS Conductivity Meter with a measurement range of 11-15 millimhos.

D-2

DIALYSATE METER™ DS Conductivity Meter with dual measurement ranges of 0-10 and 0-20 millimhos.

EP-10

DS Conductivity Meter with measurement ranges of 0-10, 100, 1000, and 10,000 µM/µS.

EP

DS Conductivity/Resistivity Meter with measurement ranges of 0-0.5, 5, 50, 500, 5000 µM/µS, and 2-30 MΩ.

RO-1

RO METER™ DS TDS Meter with a measurement range of 0-1250 ppm, featuring a color band indicator.

RO-1NC

RO METER™ DS TDS Meter with a measurement range of 0-1250 ppm, without the color band indicator.

Reviews

There are no reviews yet.

Be the first to review “DS Meters for Measuring TDS/Conductivity”
whatsapp kami!